244-130-000-204 GSI130 Galvanic Separation Units

244-130-000-204 GSI130 Galvanic Separation Units

Item Number:GSI130 244-130-000-204
Price: $1500
Lead Time: In stock
Condition: New
Payment: T/T
Shipping Port: Fujian, China
Send Inquiry
Description
Technical Parameters

The GSI130 244-130-000-204 galvanic separation unit is designed for vibration monitoring and industrial signal isolation applications. It is commonly used with Vibro-Meter / Meggitt monitoring systems to provide galvanic isolation between sensors, signal conditioners, and monitoring equipment.

GSI130 244-130-000-204 galvanic separation unit is considered an obsolete legacy product in many industrial systems. In some applications, it has been replaced by newer GSI127 series modules depending on system configuration requirements.

Features:
Galvanic isolation for industrial signal transmission
Reduces ground loop interference
Supports transducers and signal conditioners
Suitable for long-distance signal transmission
Used in vibration monitoring systems
Compatible with Vibro-Meter monitoring chains

product-620-370
Parameter Details
Model GSI130
Part Number 244-130-000-204
Description Galvanic Separation Unit
Origin Switzerland
Dimensions 15 × 15 × 5 cm
Weight 0.25 kg
HS code 9022909090
Application Vibration Monitoring System

 

Products Description

In the early vibration monitoring systems, a separate measurement chain structure was typically adopted among sensors, signal regulators, and monitoring cards. As the operational time at the site increased, long-distance wiring, multi-point grounding, and electromagnetic interference generated by large motor equipment would have a significant impact on the vibration signals.

 

244-130-000-204 GSI130 Galvanic Separation Units are mainly used in the signal isolation section of the old version Vibro-Meter / Meggitt monitoring cabinets. They establish an isolation loop between the CA series acceleration sensors, the CP dynamic pressure sensors, and the IPC704 signal regulator, aiming to reduce the impact of ground loops on the measurement chain.

 

In many legacy systems, the IPC704 adopts a 2-wire current output method for long-distance signal transmission, with a transmission distance of approximately 1 km. Such a configuration usually requires the use of the GSI series galvanic separation unit.

 

Common in the following system environments:
Legacy Vibro-Meter monitoring rack
Meggitt vibration protection systems
Steam turbine monitoring cabinet
Gas turbine vibration chain
Compressor monitoring systems

 

Among the legacy systems that are still in operation, the common associated devices include:
IPC704 signal conditioner
IQS450 signal conditioner
TQ402 / TQ412 proximity system
VE210 velocity sensor

 

The Role of Galvanic Separation in Industrial Vibration Monitoring Systems

In industrial vibration monitoring systems, sensor signals usually need to be transmitted over a long distance before entering the monitoring cabinet or signal regulation module. In the field environment, components such as frequency converters, high-voltage motors, grounding systems, and power equipment can cause potential differences and electromagnetic interference in the signal chain. These issues are particularly common in the fields of turbine machinery, compressors, and power generation units.

 

Galvanic Separation (Electrical Isolation) technology is mainly used to cut off the direct conductive path between different devices, keeping the sensor circuit isolated from the monitoring system, thereby reducing the influence of ground loop on vibration signals. This type of isolation structure is widely applied in proximity measurement chains, usually located between the sensor and signal conditioners such as IPC704 and IQS450.

 

In the previous version of the Vibro-Meter monitoring system, some dynamic signals were transmitted over long distances using the 2-wire current transmission method, with the wiring length capable of reaching approximately 1 km. If there were multiple grounding structures at the site, it was prone to cause:
Signal offset
Vibration value fluctuation
High-frequency noise superposition
Channel false alarm

Therefore, the galvanic separation unit is usually installed as an independent isolation module within the monitoring chain, to improve:
Isolation of grounding circuit, Analog signal
Long-distance signal transmission
On-site EMI interference issue

 

FAQ

Q: Has GSI130 been discontinued?

A: Currently, GSI130 244-130-000-204 is regarded as an earlier version.
Many users still purchase GSI130 for the following purposes:
Old system maintenance
Spare parts replacement
Equipment shutdown for maintenance
Extension of equipment lifecycle

Q: Does GSI130 still have any stock available?

A: As this model is an older product, the inventory quantity may vary according to market conditions. It is recommended to consult the sales manager to verify the latest prices and delivery schedules.

Q: What is Galvanic Separation?

A: Galvanic Separation (Electrical Isolation) is a technology that prevents direct electrical connections between different devices by isolating the current circuits.
Its main purposes include:
Preventing ground loops
Reducing electromagnetic interference
Protecting sensitive electronic equipment
Reducing noise in industrial environments

Q: Is GSI130 compatible with IPC704?

A: GSI130 is commonly used in the Vibro-Meter IPC704 signal regulation system.
This module is usually installed at:
Between the sensor and IPC704
Isolation position of the signal link
Inside the industrial monitoring cabinet

 

 

 

 

 

 

Hot Tags: 244-130-000-20, 244-130-000-204, GSI130, GSI130 Galvanic Separation Units, VIBRO-METER GSI130, Meggitt GSI130, GSI130 obsolete