The CA134 144-134-000-613 is a high-temperature piezoelectric accelerometer from the Parker Meggitt vibro-meter product line. It is designed for vibration measurement in demanding industrial environments, including applications involving high operating temperatures and potentially explosive atmospheres when the installation complies with the applicable certification requirements.
This version is supplied with an approximately 2 m integral mineral-insulated (MI) cable, double-braid protection, and a Vibro-Meter high-temperature connector. Its nominal sensitivity is 10 pC/g, with a specified frequency response extending from 0.5 Hz to 6,000 Hz. The standard operating temperature range is −54°C to +500°C; the separate cryogenic version has different low-temperature capabilities.


Request a Quote – CA134 144-134-000-613
For pricing, stock availability, and delivery information for the Vibro-Meter CA134 144-134-000-613 piezoelectric accelerometer, please send us your inquiry. Include the required quantity and any specific technical requirements so we can confirm the details.
Email: info@htechplc.com
Product: CA134 144-134-000-613
Quotation details: Price, availability, lead time, shipping options, and warranty terms
Product Specifications – CA134 144-134-000-613
|
Parameter |
Specification |
|---|---|
|
Model |
CA134 |
|
Part Number (PNR) |
144-134-000-613 |
|
Product Type |
Piezoelectric Accelerometer |
|
Version |
Integral Cable Version |
|
Output Type |
Charge Output |
|
Signal Configuration |
2-pin system, insulated from case |
|
Nominal Sensitivity |
10 pC/g ±5% |
|
Frequency Response |
0.5–6,000 Hz |
|
Response Tolerance |
±5% from 0.5–3,500 Hz; less than 10% from 3,500–6,000 Hz |
|
Dynamic Measurement Range |
0.001–500 g peak |
|
Overload Capacity |
Up to 1,000 g peak |
|
Linearity |
±1% over the dynamic measurement range |
|
Nominal Resonant Frequency |
Greater than 14 kHz |
|
Continuous Operating Temperature |
−54°C to +500°C |
|
Integral Cable Length |
Approximately 2 m |
|
Cable Type |
Mineral-Insulated (MI) Cable |
|
Cable Protection |
Double Braid |
|
Connector Type |
High-Temperature Connector, Hexagonal 7/16 in |
|
Housing Material |
High-Temperature Nickel Alloy and Stainless Steel |
|
Sensor Head Weight |
Approximately 120 g |
|
MI Cable Weight |
Approximately 140 g/m |
|
Mounting Hardware |
Three M4 × 16 Allen Screws and Three Spring-Lock Washers |
|
Nominal Mounting Torque |
4 N·m |
|
Hazardous Area Certification |
Refer to applicable manufacturer certificates and installation conditions |
| Origin | Switzerland |
| Dimension | 17*17*7cm |
| Weight | 0.85kg |
| HS CODE | 9029209000 |
Key Features
High-Temperature Vibration Measurement
The CA134 is designed for vibration measurement where the sensor must operate across a wide temperature range. The standard version supports continuous operation from −54°C to +500°C, subject to the manufacturer's specified installation and operating conditions.
Integral Mineral-Insulated Cable
Part number 144-134-000-613 includes an approximately 2 m mineral-insulated cable with double-braid protection. The integral construction reduces the need to select a separate cable at the sensor end and provides a high-temperature connection arrangement for the intended measurement chain.
Charge-Output Measurement
The CA134 generates an electrical charge in response to mechanical acceleration. Its output must be connected to a compatible charge converter or signal-conditioning device. Cable capacitance and the characteristics of the signal conditioner must be considered when selecting the complete measurement chain.
Hazardous-Area Applications
The CA134 product family has hazardous-area approvals. The exact protection method, certificate, and conditions of use must be checked for the specific part number and installation. The presence of an Ex approval for a product family does not remove the need to comply with the applicable site and installation requirements.
The CA134 uses a piezoelectric sensing element to convert mechanical acceleration into an electrical charge signal. When the sensor is rigidly mounted to a vibrating machine surface, the sensing element responds to the vibration transmitted through the mounting interface.
The resulting charge signal is passed through a compatible charge converter or signal-conditioning stage. The conditioned signal can then be processed by a suitable vibration monitoring or data acquisition system to evaluate machine vibration.
For the CA134 144-134-000-613, signal-chain selection is particularly important because the integral MI cable affects the electrical capacitance of the measurement chain. Verify the sensor, cable, and signal conditioner as a complete configuration before commissioning.


Compatible Systems and Typical Applications
The CA134 is a sensor rather than a standalone vibration monitoring module. It requires suitable signal conditioning and monitoring equipment.
Typical applications
Gas turbine vibration measurement.
Steam turbine vibration monitoring.
Compressor vibration monitoring.
High-temperature machinery condition monitoring.
Selected industrial installations involving potentially explosive atmospheres, subject to the applicable certification and installation conditions.
Other machinery vibration measurement applications within the sensor's specified operating range.
System integration considerations
The sensor can be considered for use in a Vibro-Meter measurement chain or a suitable data acquisition and machinery monitoring installation. However, the complete chain must be verified, including input type, charge conversion, cable capacitance, channel configuration, and any hazardous-area interface requirements.
Do not describe the CA134 as directly compatible with every VM600, DCS or PLC input. A charge-output accelerometer cannot automatically be connected to a generic voltage input without the appropriate signal conditioning.
Most importantly, the approximately 2 m MI cable on the 144-134-000-613 must be considered when choosing the signal conditioner. The manufacturer's IPC707 installation documentation identifies a cable-related limitation for CA134 integral MI cable versions used with IPC707 diagnostic functionality.
CA134 SPECIFICATIONS
Case (housing) material: Special high-temperature nickel alloy and stainless steel
Mounting: Three M4 × 16 Allen screws and three M4 spring-lock washers with a nominal tightening torque of 4 N•m (3 lb-ft).
Connector:
• • Integral cable version: high-temperature connector (Hex. 7/16″). Mates with connectors used by the recommended extension cable assemblies (vibro-meter® 7/16″-27UNS-2B or CG505).
Recommended cable assemblies:EC069, EC112, EC119, EC222 or EC390.
Recommended extension cable: EC119, EC222, or EC390.
Integral cable version:

Selection Recommendation:
The CA134 series is mainly divided into two versions:
144-134-000-203: Sensor body (without cable)
144-134-000-613: Version with MI cable
High-temperature environment → Select 000-613
Requires custom cable → Select 000-203
Dangerous area → Must choose the model with Ex certification
How to use the CA134 piezoelectric accelerometer
Installation Suggestions
Use rigid installation (threaded fixation)
Avoid installation on loose or resonant structures
The cable should be kept away from high electromagnetic interference sources
Supporting equipment
The CA134 provides a charge output and requires a compatible charge converter or signal-conditioning device. For the integral MI cable version 144-134-000-613, verify the complete measurement-chain compatibility before selecting the signal conditioner.
Signal processing
It is recommended to use the following systems in combination:
Vibration monitoring system (such as Vibro-Meter VM600)
DCS system
Data acquisition system

ACCESSORIES
Cable assemblies:
--EC069 921-069-000-x01 High-temperature MI cable assembly
--EC112 921-112-000-5x1 MI cable assembly with LEMO connector
--EC119 922-119-000-003 Cable assembly with CG505 connector and flying leads
--EC222 922-222-000-002 Cable assembly with CG505 connector and flying leads
--EC390 922-390-000-003 Shielded cable assembly with sealed flexible protection
Mounting adaptors:
--TA104 144-136-301-101
Mounting adapter for CA/CE13x and CA/CE28x, with stainless-steel hexagonal base with M8 stud. Refer to product drawing 144-136-301D101.
--TA105 144-136-302-101
Mounting adapter for CA/CE13x and CA/CE28x, with thermally isolating base (300°C, 572°F). Refer to product drawing 144-136-302D101.
Packaging and International Shipping
Each CA134 144-134-000-613 shipment should be packed according to the actual sensor and cable configuration.
Sensor protection: Protect the sensor head and connector against impact and contamination.
Cable protection: Secure the 2 m integral MI cable without exceeding its minimum bend radius or placing excessive force on the connector.
Moisture protection: Use appropriate protective materials according to the route and storage conditions.
Export packaging: Use a suitable carton and internal cushioning, with additional protection where necessary.
Shipping documents: Prepare the commercial invoice, packing list, and other agreed documents as applicable.
Courier options: DHL, FedEx, UPS or TNT, subject to destination coverage and shipment acceptance.
Dispatch confirmation: Confirm stock availability and estimated dispatch time before accepting the purchase order.
Actual dispatch dates, transit times, freight costs, and delivery terms must be confirmed for each order.
faq
Lorem ipsum dolor sit amet consectetur adipisicing elit.
Q:1. What is the difference between 144-134-000-613 and 144-134-000-203?
A:The 000-613 version includes an approximately 2 m integral MI cable. The 000-203 version is the sensor-only variant. Cable configuration and measurement-chain compatibility must be checked before selecting a replacement.
Q:2. What is the sensitivity of the CA134?
A:The nominal sensitivity is 10 pC/g ±5%, specified at 120 Hz with a 5 g input under the manufacturer's stated calibration conditions.
Q:3. What is its frequency response?
A:The specified frequency response is 0.5–6,000 Hz. The response tolerance is ±5% from 0.5 to 3,500 Hz and less than 10% from 3,500 to 6,000 Hz.
Q:4. What is the operating temperature range?
A:The standard version supports continuous operation from −54°C to +500°C. A separately configured cryogenic version supports a minimum operating temperature of −253°C. Verify the exact version before ordering.
Q:5. Is this sensor suitable for gas turbines?
A:It is designed for vibration measurement in demanding environments, including gas turbine applications. The mounting location, vibration range, temperature, cable routing and monitoring system must be suitable for the application.
Q:6. Can it connect directly to a PLC or DCS analog input?
A:Not generally without suitable signal conditioning. The sensor provides a charge output, so the interface must be designed for that signal type before connecting to a monitoring or control system.
CA134 Piezoelectric Accelerometer - Data Sheet