200-560-000-016 IOC4T Input/output Card

200-560-000-016 IOC4T Input/output Card

Item Number:200-560-000-016 IOC4T
Price: $1500
Lead Time: In stock
Condition: New
Payment: T/T
Shipping Port: Fujian, China
Send Inquiry
Description
Technical Parameters
IOC4T Input/Output Card
 

200-560-000-016 IOC4T Input/Output Card is a signal interface card used in the machinery protection system. It is mainly installed in conjunction with the MPC4 machinery protection card within the VM600 rack system and is used for interface processing of vibration signals, rotational speed signals, and alarm outputs.

This module is installed at the rear of the MPC4 card and is used to expand the input and output of the vibration monitoring system, including dynamic vibration channels, tachometer speed input, relay output, and analog output interfaces. IOC 4T is commonly used in rotating machinery monitoring projects such as steam turbines, gas turbines, compressors, and generator protection systems.

Before purchasing, it is necessary to confirm the complete order number to ensure the supply of the corresponding products.

Technical Specifications  
Model IOC4T
Part Number 200-560-000-016
Description Input/Output Card
Product Line VM600
Compatible Card MPC4
Dynamic Inputs 4 Channels
Tachometer Inputs 2 Channels
Analog Outputs 0–10 V / 4–20 mA
Relay Outputs 4 Relays
Origin Switzerland
Dimensions 21 × 17 × 5 cm
Weight 0.35 kg
HS code 8471800000

 

In the Monitoring rack, 200-560-000-016 IOC4T is responsible for converting the signals from on-site sensors to the monitoring system and transmitting alarm status, relay signals, and analog output to PLC, DCS, or external protection systems. The module supports 4 dynamic input channels and 2 speed input channels, which can be used for shaft vibration, shell vibration, displacement, and speed measurement chains.
This card applies to:

VM600 machinery protection systems

Vibro-Meter monitoring racks

API 670 vibration monitoring applications

Industrial rotating machinery protection systems

Oil & Gas machinery monitoring

Power plant turbine monitoring systems

 

In the input/output interface section, 200-560-000-016 IOC4T adopts an EMI/EMC protection design, which is used to reduce:

Electromagnetic interference

Ground noise

Signal distortion

Long-distance transmission interference

 

This type of structure is commonly found in:

Power plant turbine cabinets

Oil & Gas compressor systems

High-voltage industrial environments

Rotating machinery monitoring systems

The role of IOC4T in the VM600 system

The IOC4T is mainly used as an interface expansion module for the MPC4 machinery protection card. This module is installed at the rear of the VM600 rack and forms a complete machinery protection channel together with the front MPC4 card.

In the large-scale rotating equipment monitoring system, the on-site vibration signals usually come from:

Proximity probes

Velocity sensors

Accelerometers

Tachometer sensors

 

IOC4T is used to receive and process these input signals, and at the same time, it outputs the monitoring results to:

DCS systems

PLC systems

Alarm systems

Turbine control systems

 

This Input/Output Card supports:

Dynamic vibration input
Speed input, Relay alarm output
Buffered output
Analog signal output

Dynamic Signal & Tachometer Processing

IOC4T supports 4 dynamic measurement channels, which can be used for vibration signal acquisition.
These channels are typically connected as follows:

TQ series proximity systems

Velocity transducers

Acceleration sensors

In the API 670 vibration protection applications, the rotational speed signal and the vibration signal usually need to be processed synchronously. Therefore, IOC4T will be used together with MPC4 in the complete mechanical protection system architecture.

Analog Output & Relay Interface

IOC4T provides:

0–10 V analog outputs

4–20 mA signal outputs

Relay output interfaces

These interfaces are used to transmit vibration monitoring data to an external system.

 

Hot-Swappable Card Structure

IOC4T adopts the modular rack architecture from the VM600 system and supports online plug-and-play maintenance.

In some system configurations, the on-site engineer can operate without shutting down the entire rack.

Card replacement
Maintenance inspection
Channel troubleshooting

Compatible Modules & Systems
 

The common supporting modules of IOC4T include:

MPC4 Machinery Protection Card

RLC16 Relay Card

IRC4 Interface Relay Card

ABE056 Rack

ABE04x Rack

VM600 Rack System

Related Products

 

 

MPC4 Machinery Protection Card

RLC16 Relay Card

IRC4 Interface Relay Module

TQ402 Proximity System

TQ412 Proximity System

IQS450 Signal Conditioner

Inventory & Supply Information

 

At present, IOC4T 200-560-000-016 is still widely used in the Vibro-Meter VM600 machinery protection system.

Spare parts demand

Shutdown maintenance demand

Turbine overhaul projects

Legacy monitoring system replacement requirements

 

The current supply forms include:

New surplus stock

Factory sealed inventory

Tested surplus units

FAQ

 

 

Q: Is IOC4T necessarily required to be used in conjunction with MPC4?

A: The IOC4T itself is a post-processing interface card of MPC4 and is usually not operated independently.
In the VM600 system architecture:
The front part is the MPC4 machinery protection card
The rear part is the IOC4T input/output card

 

Before purchasing, the following usually need to be confirmed:
The current MPC4 model
VM600 rack type
Channel configuration requirements

Q: Where is IOC4T installed?

A: IOC4T is installed on:
Back of VM600 rack
Behind the MPC4 card slot

It is a rear I/O interface card.

Q: What information needs to be confirmed before purchasing IOC4T?

A: Confirm the following items: Part Number
MPC4 companion model
VM600 rack type
Channel configuration requirement, Relay output requirements
Analog output type
Project usage environment

 

 

 

 

Hot Tags: 200-560-000-016, IOC4T Input/output Card, VM600 200-560-000-016, machinery protection, vibration monitoring