WOODWARD 5437-672 NETCON FIELD TERMINAL

WOODWARD 5437-672 NETCON FIELD TERMINAL

Item Number:5437-672
Brand: WOODWARD
Price: $850
Lead Time: In stock
Condition: New
Payment: T/T
Shipping Port: Fujian, China
Send Inquiry
Description
Technical Parameters

5437-672 is a field terminal device that can provide connections to sensors, actuators, or other field devices. The module provides communication interfaces to allow the exchange of analog and digital signal data with the control system. The module provides different input/output (I/O) signal types that can include analog (4-20 mA, 0-5V) signal types as well as digital signal types. The module can be adapted to various types of industrial machinery.

In 1997, Woodward created a small DIN-rail-mountable filter that is specifically designed to eliminate noise created by the actuator excitation within a tight frequency band (notch) around 3000 Hz. The unit requires about 1 inch (25 mm) of DIN rail space under the actuator FTM, and has two wire connections. One wire is connected from TB 1 to the actuator excitation (–), which on Woodward FTM 5437-672 is terminal TB 6. The second wire is connected from TB 4 to ground.

5437-672

 

Technical Specifications

Brand

WOODWARD

Model

5437-672
Description NetCon Field Terminal Module

Communication protocol

CAN J1939 / Modbus RTU
Analog input 8 channels
Digital I/O 12 channels

Origin

USA

Dimension

10*10*8cm

Weight

0.25kg

 

 

System-related products

 

The product "WOODWARD 5437-672" belongs to the NetCon Field Terminal Module (FTM), and its main function is:
 Connect the on-site equipment ↔ Control System (DCS / PLC / MicroNet)

 

5437-672 is not usually used alone; it must be combined with system components:

MicroNet Controller
5400 Series Control Unit

Controller

Analog Input Module
Digital output module

I/O module

24V DC power module
Redundant power system

Power module

NetCon communication module
Industrial bus interface

Communication module

Sensor (temperature/pressure)
Actuator (valve/drive)

HIGH QUALITY SERVICES

Shielded signal cable
Terminal block
Communication line

Cables and Accessories

 

 

Installation and Usage

 

Fixed 5437-672

Installed in the control cabinet or rack

 

Power connection

Connect to a 24V DC power supply

 

On-site signal wiring

Connect the following devices:
Analog quantity: 4-20mA / 0-5V
Digital quantity: Switching signal
Speed signal: Electromagnetic sensor

 

Communication connection

Communication connection is connected to:
MicroNet Controller
PLC / DCS System

 

Communication method:
Modbus RTU
CAN J1939

 

Software and parameter configuration

Key configuration items:
Communication address (Node ID) Baud rate
Input/Output Type
Calibration Parameters

 

Debugging process:
Power-on inspection of LED status
Test communication for normality
Verify input signals
Confirm output control

 

 

Related Introduction

Woodward Notch Filter:

 Reference Part Number: 5437-845

 Reference Drawing Number: 9933-651

 2 Channel Actuator Controller Modules 5501-428, -429, -430, -431, -432

 

NetCon, MicroNet, and MicroNet Plus control systems with multiple 2 CH Actuator modules (part numbers 5501-428, -429, -430, -431, 432) have a potential for a 'beat' frequency to be created around 3000 Hz. This signal may create noise within the chassis and has been known to cause fluctuations in low-amplitude signals such as RTDs and thermocouples. It may cause increased noise on other analog signals as well.

 

The source of the problem is that each actuator module produces a feedback (either LVDT or RVDT) excitation signal that is independent and asynchronous from the other actuator modules generating the same output. Since these signals are likely to be slightly offset in frequency and amplitude, it is possible that a corresponding beat frequency can develop on the chassis backplane and on the analog common line.

 

Woodward's engineering services group recommends the use of one Notch Filter per chassis for all chassis that utilize two or more actuator modules. In the case of a redundant system, two filters can be installed to ensure that this protection is available during all running conditions. If a control system has multiple chassis, each chassis meeting these criteria should have a filter.

 

-
 
This industry
 

As a professional supplier of industrial automation products, we are well aware of the importance that every customer attaches to reliability, response speed, and long-term support. Therefore, in addition to providing Westinghouse APL550/878/1 digital output boards and other industrial control modules, we also offer end-to-end service guarantees to ensure a smoother procurement and implementation of your project.

Original and genuine product guarantee

Increase inventory and ensure prompt delivery

Global supply network

Customized procurement and bulk discounts

 

 

 

 

 

Hot Tags: 5437-672, WOODWARD 5437-672, Field Terminal Module, 5400 Series NETCON FIELD TERMINAL