IQS452 204-452-000-221 Signal Conditioner

IQS452 204-452-000-221 Signal Conditioner

Item Number:IQS452 204-452-000-221
Price: $2000
Lead Time: In stock
Condition: New
Payment: T/T
Shipping Port: Fujian, China
Send Inquiry
Description
Technical Parameters
204-452-000-221 Signal Conditioner

 

 

IQS452 204-452-000-221 is a Signal Conditioner of the Proximity Measurement System, which is used in conjunction with TQ402 or TQ412 non-contact eddy current probes and EA402 Extension Cable to form a complete shaft vibration and shaft displacement measurement system. The entire measurement chain adopts the eddy current (Eddy Current) non-contact measurement principle, capable of continuously detecting key mechanical state parameters such as relative vibration, axial displacement, and gap changes of the rotating machinery shaft.

During the operation of large rotating equipment, problems such as bearing wear, shaft misalignment, thermal expansion, rotor imbalance, and coupling eccentricity can cause changes in the shaft's center position. The IQS452 processes the distance-change signals collected by the probe, enabling the monitoring system to continuously monitor the equipment's operating status and providing continuous data support for predictive maintenance, condition monitoring, and equipment protection.

Parameter Specification
Product Name IQS452 Signal Conditioner
Model Number 204-452-000-221
Product Type Eddy Current Signal Conditioner
Measurement Principle Non-contact Eddy Current Technology
Compatible Proximity Probes TQ402, TQ412
Compatible Extension Cable EA402
Measurement System Vibro-Meter Proximity Measurement System
Measuring Range 2 mm or 4 mm (depending on version)
Total System Length 5 m or 10 m
System Calibration Target VCL 140 Steel (1.7225)
Interchangeability Fully interchangeable within the calibrated proximity system

Dimension

15*14*5cm

Weight

0.35kg

HS code 8529905000

 

Supply Voltage –20 VDC to –32 VDC
Supply Current 13 ± 1 mA (25 mA max.)
Frequency Response DC to 20 kHz (–3 dB)
Output Type Voltage Output (3-wire) or Current Output (2-wire)
Voltage Output Range –1.6 V to –17.6 V
Voltage Dynamic Range 16 V
Voltage Output Impedance 500 Ω
Short-Circuit Current 45 mA
Current Output Range 15.5 mA to 20.5 mA
Current Dynamic Range 5 mA
Output Capacitance 1 nF
Output Inductance 100 μH

 

Operating Temperature –30°C to +70°C
Storage Temperature –40°C to +80°C
Relative Humidity Maximum 95%, Non-condensing
Vibration Resistance 2 g peak (10 Hz to 500 Hz)
Protection Class IP40

 

ATEX LCIE 02 ATEX 6086 X
CSA Class I, Division 1 & 2
Hazardous Area Zone 1 / Zone 2 (Applicable versions only)

 

Sensitivity Options

Different IQS452 versions provide different sensitivity configurations to meet various machine protection and shaft vibration monitoring requirements.

IQS Type Measuring
Range
Mode Sensitivity Total System
Length
Version Ordering Number
IQS 452,
versions
M0XX
or M1XX
4 mm Voltage
output,
3-wire
configuration
4 mV/μm 5m
10m
5m
10m
Standard
Standard
Exi
Ex
204-452-000-01
204-452-000-02
204-452-000-03
204-452-000-04
Current
output,
2-wire
configuration
1.25 μA/μm 5m
10m
5m
10m
Standard
Standard
Exi
Ex
204-452-000-11
204-452-000-12
204-452-000-13
204-452-000-14
IQS 452,
versions
M2XX
or M3XX
2 mm Voltage
output,
3-wire
configuration
8 mV/μm 5m
10m
5m
10m
Standard
Standard
Exi
Ex
204-452-000-21
204-452-000-22
204-452-000-23
204-452-000-24
Current
output,
2-wire
configuration
2.5 μA/μm 5m
10m
5m
10m
Standard
Standard
Exi
Ex
204-452-000-31
204-452-000-32
204-452-000-33
204-452-000-34

 

The IQS452 Signal Conditioner is available in multiple versions with different output modes, sensitivities, measuring ranges, and hazardous area approvals. The 204-452-000-221 model belongs to the IQS452 product family. Before ordering, users should verify the required measuring range, output configuration, total system length, and certification requirements to ensure compatibility with the existing proximity measurement system.

 

Key Features

--Utilize the non-contact electro-vortex flow measurement principle

IQS452 204-452-000-221

The IQS452 is based on the mature Eddy Current technology. It drives the TQ402 or TQ412 probe with high-frequency alternating signals, creating an electromagnetic field on the surface of the metal target. When the distance between the shaft and the probe changes, the eddy currents generated on the metal surface also change. The IQS452 converts this change into a linear voltage or current output, enabling continuous distance measurement.
Since the entire measurement process does not require mechanical contact, it will not cause wear on the measured shaft or affect the normal operation of the equipment.

 

--Provide voltage output or current output

The IQS452 supports two standard output methods:
-Voltage Output (3-wire system)
Suitable for most vibration monitoring systems.
Output range:
Minimum Gap: -1.6 V
Maximum Gap: -17.6 V
Dynamic Range: 16 V

-Current Output (2-wire system)
Suitable for long-distance transmission and industrial control systems.
Output range:
15.5 mA
20.5 mA
Dynamic range: 5 mA

 

--The system supports interchangeable installation.

The Proximity System where IQS452 is located has been factory-calibrated, and the components within the same system can be used interchangeably.
Including:

IQS452 Signal Conditioner
TQ402 Probe
TQ412 Probe
EA402 Extension Cable

 

Product Details

Q: Can IQS452 be used independently?

A: The IQS452 is not an independent device. It must be used in conjunction with the TQ402 or TQ412 Proximity Probe as well as the EA402 Extension Cable to form a complete Proximity Measurement System. Only when the entire measurement chain is correctly matched and calibrated can accurate measurement results be obtained.

Q: What is the working power supply for IQS452?

A: The power supply voltage range of IQS452 is from –20 VDC to –32 VDC. The standard operating current is approximately 13 ± 1 mA, and the maximum operating current does not exceed 25 mA. Before installation, it is necessary to confirm that the on-site power supply meets the product requirements.

Q: What information needs to be provided when purchasing the IQS452?

A: It is recommended to provide the following information:
Full order number of the original product
Photo of the product nameplate
Compatible probe model (TQ402 or TQ412)
Extended cable length of EA402
Output mode (voltage or current)
Measurement range (2 mm or 4 mm)
Whether explosion-proof certification is required
Model of the monitoring system used (such as VM600)

Q: How can we determine if IQS452 is suitable for the user's device?

A: The most effective method is to provide the complete order number of the original IQS452 equipment, a photo of the nameplate, or the equipment BOM list. Our technical team can assist in confirming compatibility based on the product version, output method, probe model, system length, and application environment, and recommend the corresponding configuration to help reduce procurement risks and ensure that the product can be used normally in conjunction with the existing system.

 

 

 

 

 

Hot Tags: 204-452-000-221, IQS452 204-452-000-221, IQS452 Signal Conditioner, Vibro-Meter IQS452, IQS452 VM600, 204-452-000-221 Proximity System