Product Introduction
The A6500-SR System Rack is part of the AMS 6500 ATG machinery protection system. It is a 19" rack (84HP width and 3RU height). The System Rack allows you to install up to 11 protection cards (two-channel A6500-UM Universal Measuring Card and/or four-channel A6500-TP Temperature Process Cards), one A6500-RC Relay Card, and one A6500-CC Com Card - two Com Cards for redundant communication.
Technical Specifications
|
Manufacture |
EMERSON |
|
Model |
A6500-SR |
|
Part Number |
A6500-SR |
|
Description |
System Rack |
|
Origin |
Germany |
|
Dimension |
45*25*15cm |
|
Weight |
2.55kg |
Product Details
A6500-SR rack dimensions: 19-inch standard (84HP wide × 3RU high) rack structure, in compliance with IEC 60297 standards.
Protection level:
Installed in the cabinet: IP20 (in accordance with IEC 60529). Profess
Not installed: IP00 (without protection).
The types of modules supported by the rack
The A6500-SR is not a single-function device, but rather a system that can accommodate the following typical modules (cards):

A6500-UM Universal Measurement Card
It is used for collecting various parameters such as vibration, speed, displacement, shaft eccentricity, and shell vibration.

A6500-TP Temperature/Process Card
It is used for collecting temperature sensors such as RTD/thermocouples, as well as standard process signals of 0-10V/0/4-20mA.

A6500-RC Relay Module
Provide logical judgment and output relay functions, such as alarm trigger output, etc.

A6500-CC Communication Card
Provide communication capabilities for the system (such as Modbus RTU, Modbus TCP/IP, OPC UA, and USB connections etc.).
The A6500-SR adopts a modular card-insertion structure, enabling users to install cards with different functions according to the monitoring requirements at the site. For example:
Install multiple general-purpose measurement cards to increase the number of measurement channels.
Install temperature and process input cards to expand temperature monitoring.
Utilize communication cards to achieve system networking and remote access.
When choosing the A6500-SR as the system carrier, the following elements should be taken into consideration:
Measurement channel requirements: Estimate the number of UM universal measurement cards required.
Temperature/Process Monitoring Requirements: Do we need temperature/process cards?
Alarm/Control Output Requirements: Do you need a relay card?
Communication and redundancy requirements: Do we need dual communication cards for redundancy?
On-site environmental factors: Whether a higher level of protection or noise reduction measures is required.
FAQ
Q: A6500-SR Rack Size
A: 19-inch standard (84HP wide × 3RU high) rack structure, in compliance with IEC 60297 standards.
Q: Rack storage temperature
A: -40°C to +85°C
Q: Module Slot:
A: It can accommodate up to 11 monitoring modules (such as measurement cards, temperature/process cards, etc.).
One relay module slot. 1 to 2 communication card slots (redundant communication).