HIMA F8652X Central Module

HIMA F8652X Central Module

Item Number: F8652X
Brand: HIMA
Price: $6500
Lead Time: In stock
Condition: New
Payment: T/T
Shipping Port: Fujian,CN
Send Inquiry
Description
Technical Parameters
Product Introduction

The HIMA F8652X safety control central processing module is used in the construction of safety instrument systems in industrial processes. As the core unit of the entire SIS, it is responsible for executing safety logic, monitoring system status, managing communication, and performing fault self-diagnosis, enabling real-time processing and control of critical safety logic in the industrial field.

 

Technical Specifications

 

Brand

HIMA

Model

F8652X

Part Number

F8652X

Description

safety control central module

Origin

Germany

Dimension

21*15*7m

Weight

0.4kg

 

Product Details

The F8652X internally employs redundant CPUs to run safety logic programs, which can:
Real-time acquisition of input signals and logical judgment
Implementing complex security rules and decisions
Output the driving signals that conform to logical judgments (either directly controlling the on-site equipment or triggering actions through the I/O module)
Interacting and working with remote I/O and field devices

 

Product Parameters:

Processor: Intel 386EX.

Storage: Flash-EPROM 1 MB (user program), Flash-EPROM 1 MB (operating system), SRAM 1 MB (data).

Number of I/O points: Analog input/output: 4 points; Digital input/output: 32 points.

Communication interface: Ethernet, RS485, PROFIBUS DP, USB.

Protection level: IP20.

Operating temperature range: -20°C to 70°C or -40°C to 70°C.

 

Product Features:

High-performance processor: ensures fast system response and efficient processing.

Large-capacity storage: provides ample storage space to store large amounts of programs and data.

Modular design: flexible configuration, expandable according to system requirements.

Safety certification: complies with IEC 61508 functional safety standards, suitable for SIL 3 applications.

Redundant design: a dual-processor redundant design is adopted to improve system reliability.

 

Product Function And Use:

As the core of the safety instrument system, it realizes the safety control of the entire system.

Perform complex safety logic operations and make safety decisions.

Process various data from field devices and make analyses and judgments.

Provide a human-computer interaction interface to facilitate user configuration and monitoring.

 

F8652X HIMA

The built-in self-diagnosis mechanism of F8652X includes:
✔ Watchdog ensures program continuity
✔ Consistency check between channels confirms consistency of redundant CPU outputs
✔ Communication link monitoring captures disconnection or abnormal signals
✔ Health checks for internal storage, buses, and I/O
When an anomaly is detected, the system will automatically switch to the safe state (Safe State), which means it will stop any potentially dangerous actions to ensure the safety of the equipment and personnel.

 

F8652X can be integrated with remote I/O expansion modules, sub-control nodes, sensors, and actuators through the safety bus or fieldbus. Such a design is beneficial for:
✔ Reduce the complexity of on-site wiring
✔ Achieve a distributed control structure
✔ Support remote diagnosis and node maintenance

Installation and commissioning

F8652X is usually developed, configured, a nd debugged in conjunction with the safety engineering software provided by HIMA, for example:
✔ HIMatrix / SILworx
✔ Supports IEC 61131-3 programming languages (ladder diagram, function block diagram, structured text, etc.)
This environment supports:
Offline simulation verification and online debugging
Redundant configuration settings
Module Diagnosis and Condition Monitoring

 

When deploying F8652X, the following points should be noted:
✔ Power redundancy: Ensure e stable 24 V DC power supply and prioritize the use of redundant power modules.
✔ Communication network planning: The topology of the redundant safety bus should match the communication protocol.
✔ I/O address mapping and logical verification: The logical program needs to verify that each I/O point is consistent with the on-site equipment.
✔ Diagnostic mechanism activation: Enable internal diagnosis and system log recording to facilitate maintenance and fault tracking.

 

 

When selecting the model F8652X, the following factors should be taken into consideration

Contact:  info@htechplc.com

01

Safety level requirement (SIL 3 or higher)

02

Redundancy and fault tolerance requirements

03

On-site I/O points and expansion space

F8652X safety control central

 

 

 

 

 

 

Hot Tags: HIMA F8652X Central Module, China HIMA F8652X Central Module manufacturers, suppliers