Description
Technical Parameters
Product Introduction
PL9700X11AXXX is a GE Multilin EPM 9700 Power Quality and Energy Meter. The Multilin EPM 9700 is a high-performance power quality meter with advanced logging capabilities and flexible communication options. As a member of GE's EPM meter family, the EPM 9700 provides a comprehensive picture of power quality and consumption for metered points within an electrical system, empowering users to make power-related analysis and decisions quickly and effectively, as well as recording data for accurate reconciliation.

Technical Specifications
|
Manufacture |
General Electric(GE) |
|
Model |
PL9700X11AXXX |
| Part Number | PL9700X11AXXX |
|
Description |
Multilin EPM 9700 |
|
Origin |
USA |
|
Dimension |
30*20*10cm |
|
Weight |
0.5kg |
Product Details
The EPM 9700 meter is equipped with extensive communication capabilities that allow it to speak with many different SCADA or other communication systems simultaneously. The meter has 6 communication ports as a standard offering. These ports include 4 serial ports and 2 Ethernet-based communication ports. The Ethernet ports include an SST-terminated fiber optic port and an RJ45 port. Both ports use separate IP addresses so that they can run on simultaneous redundant networks.
1. Details of Ports
• 6 standard COM ports
• 4 serial ports - RS485 (one of the ports is RS485/RS232 selectable)
• 2 independent Ethernet ports - RJ45 and Fiber Optic
• Modbus RTU, Modbus ASCII, Modbus TCP/IP, DNP 3.0 Level 2 communication
• All ports can communicate simultaneously
• Each Ethernet port can be assigned a separate IP address
2.8 Built-in Digital High-speed Status Inputs
• Inputs automatically sense whether the circuit is externally wetted
• If externally wetted, input up to 150 VDC is accepted
• If internally wetted, the meter supplies the necessary voltage for the control application
3. VAUX Input
• Neutral to ground or aux voltage readings
• Synchronizing schemes, for example, obtaining the frequency, magnitude, and phase angle on both sides of a switch or between the generator and bus voltage
4. Two Standard Pulse Outputs
• Solid State, form-A, 35 ohm max on resistance
• 120 mA continuous, 350 mA max for 10 ms
• Peak voltage: 350 V DC • Switching rate max: 10/s
• Support pulse-counting applications
PL9700X11AXXX Advanced Monitoring and Metering:
• 0.06% Energy Accuracy (ANSI 0.2% Accuracy Class)
• Harmonics to the 511th order voltage, current, 127th order in real time
• Up to 1024 samples/cycle-based measurements
• Up to 1.2 GB of logging memory with default preconfigured logging of 142 essential parameters
• Updated IEC 61000-4-30 Class A Edition 3 Power Quality Measurement and EN50160 Reporting Support
PL9700X11AXXX Advanced Communications and Control:
•6 standard communications ports supporting serial (RS232, RS485); Ethernet (RJ45, ST Fiber Optic independent ports, unique IP)
• Support for Modbus, DNP 3.0 protocols
• Easy system integration with standard pulse outputs and digital inputs, as well as expandable external analog, digital, and relay outputs
Applications:

• Power quality alarming/event capture for utility or industrial event investigation/reconciliation, ensuring uptime and predictive maintenance for critical power quality sensitive assets utility substation, data centers, manufacturing, and hospitals
• Revenue energy billing or reconciliation (demand, time of use), and for utility or industrial applications
• High-speed data capture and control in applications such as generation or renewables
• Specialized utility/industrial power quality reporting for Class A IEC 61000-4-30 Ed. 3, IEC 61000-4-15 Flicker, IEC 61000-4-7 Harmonics, and EN50160 standards
Ordering Codes:
EPM 9700 Meter
| Base Unit | PL9700-- | X | * | * | * | X | X | X | Description |
| X | EPM 9700 Multi-function metering system | ||||||||
| Frequency | Reserved for future use | ||||||||
|
|
0 1 |
60 Hz AC frequency system 50 Hz AC frequency system |
|||||||
| Control Power |
0 1 |
Universal (100-240) VAC @50/60 Hz or (100-240) VDC 18 to 60 VDC |
|||||||
| Software |
A B |
Standard: 512MB Memory, 512 Samples/Cycle Advanced: 1.2GB Memory, 1024 Samples/Cycle |
|||||||
| X | X | X | Reserved for future use |
EPM 9700 Display and Accessories:
| GE PART NUMBER | DESCRIPTION | |
| Display | PL9000P40NPLUS0 | P40NPLUSThree-line LED Display with 6ft cable |
| Display cables | PL9000ACC420 | P40NPLUS Display Cable only - 20 ft. length |
| External Input/Output (I/O) Modules | ANALOG OUTPUT MODULES | |
| PL90001MAON4O00 | 4 Channel 0-1 mA Analog Outputs | |
| PL90001MAON8O00 | 8 Channel 0-1 mA Analog Outputs | |
| PL90002OMAON400 | 4 Channel 4-20 mA Analog Outputs | |
| PL90002OMAON800 | 8 Channel 4-20 mA Analog Outputs | |
| ANALOG INPUT MODULES | ||
| PL90008AI100000 | 8 Channel 0-1mA Analog Inputs | |
| PL90008AI200000 | 8 Channel 4-20mA Analog Inputs | |
| PL90008AI300000 | 8 Channel 0-5V DC Analog Inputs | |
| PL90008AI400000 | 8 Channel 0-10V DC Analog Inputs | |
| Digital Dry Contact Relay/Solid State Pulse Outputs | PL90004RO100000 | 4 Relay Outputs, 5A, 250VAC/30 VDC, Form C Latching |
| PL90004PO100000 | 4 Solid State Pulse Outputs, Form A or C KYZ Pulses, 20 Pulses/sec. Max. | |
| Digital Status Inputs | PL90008DI100000 | 8 Channel Auxiliary Digital Status Inputs |
| I/O Power Supply | PL9000PSIO00000 | Auxiliary Power Supply (Required for External I/O Modules) |
| I/O Mounting Bracket | PL9000MBIO00000 | Mounting Bracket (Required for External I/O Modules) |
| EPM 9700 DIN Rail Mount Kit | PL9000ACCDIN | EPM 9700 DIN Rail Mount Kit |
| Software License | PLSOFTCOMS | GE Communicator - EPM Meter Setup Software License |