WOODWARD 8440-1546 H MFR2 Multifunction Relay

WOODWARD 8440-1546 H MFR2 Multifunction Relay

Part Number: 8440-1546
MFR 2 Configuration: MFR2S45B/A2CDD06D09HI1I4JK24M
Product Family: MFR 2
Product Type: Multifunction Relay
Application: Generator Protection, Synchronization, Power Management
Condition: New / Original, subject to actual availability
Stock: Contact us for current inventory
Warranty: 12 Months
Send Inquiry
Description
Technical Parameters

 

Woodward 8440-1546 is a configured MFR 2 Multifunction Relay used in generator protection, synchronization, monitoring, and power-management applications. The identifiable configuration associated with this part number is MFR2S45B/A2CDD06D09HI1I4JK24M. Woodward-SEG's legacy equipment replacement database lists 8440-1546 with this MFR2 configuration and identifies 8440-1936 / EASYGEN-3500-5/P2 as a similar replacement item.

The MFR 2 is not simply a digital speed controller. It is a multifunction generator relay designed to monitor electrical parameters and perform protection and control functions associated with generator and mains operation. The MFR 2 documentation describes functions including generator overload, reverse/reduced power, unbalanced load, overcurrent, ground fault, reactive power, frequency and voltage monitoring, mains protection, mains decoupling, and centralized alarm functions.

Request a Quote

For replacement projects, customers should provide the existing nameplate photograph and complete part number before ordering. Different MFR 2 configurations can have different electrical inputs, option packages, and application functions.

8440-1546 H MFR2

 

 

Woodward 8440-1546 Product Identity
Brand Woodward
Product Family MFR 2
Series MFR 2 Multifunction Relay
Part Number 8440-1546
Complete Configuration MFR2S45B/A2CDD06D09HI1I4JK24M
Product Type Multifunction Relay
Main Application Generator protection and control
Generator Configuration Synchronous generator configuration
CT Configuration 5 A secondary
PT Configuration 400 Vac secondary configuration
Mounting Flush mounting
Power Supply 24 Vdc class supply
Communication Configuration dependent
Product Status Legacy MFR 2 generation
Condition New / Original subject to availability
Software / Firmware Configuration dependent

Origin

USA

Dimension

25*25*15cm

Weight

0.45kg

 

Main Functions of Woodward 8440-1546
 
 

 

 

Generator Protection

One of the principal functions of the MFR 2 is monitoring and protecting the generator against abnormal electrical operating conditions.

Depending on the exact configuration, the MFR 2 family supports functions such as:

Generator overfrequency

Generator underfrequency

Generator overvoltage

Generator undervoltage

Generator overload

Reverse power / reduced power

Overcurrent protection

Ground fault monitoring

Unbalanced load monitoring

Reactive power monitoring

Generator voltage monitoring

Generator frequency monitoring

Battery voltage monitoring

 

 
 

Generator and Mains Monitoring

In applications where the generator operates together with a utility network, the MFR 2 can evaluate both generator-side and mains-side electrical parameters.

Typical monitored parameters include:

Voltage

Frequency

Current

Phase relationship

Asymmetry

Active power

Reactive power

Breaker-related status

Mains operating condition

This makes the MFR 2 suitable for generator switchgear and power-management systems where the controller must distinguish between normal operation, abnormal generator condition, and mains disturbances.

 
 

Synchronization

The MFR 2 can be used as part of a generator synchronization system.

Before closing a generator circuit breaker onto a live bus or utility network, the control system must evaluate the electrical relationship between the generator and the bus/mains.

Typical synchronization parameters include:

Generator voltage

Bus voltage

Generator frequency

Bus frequency

Phase relationship

Breaker status

The MFR 2 family is designed to support generator/mains control applications that require synchronization and breaker coordination.

 
 

Load and VAR Sharing

The MFR 2 can also be used in systems where several generator units operate together.

In multi-generator installations, the control system may need to coordinate:

Active power
Reactive power
Generator loading
Load distribution

 

This makes the device relevant to:

Parallel generator systems

CHP plants

Industrial power stations

Standby generator installations

Generator-to-grid parallel operation

 

 

MFR2S45B Configuration
 
 

Woodward-SEG's legacy replacement database identifies the complete configuration associated with 8440-1546 as:

MFR2S45B/A2CDD06D09HI1I4JK24M

Code Configuration Meaning
MFR2 MFR 2 Multifunction Relay
S Synchronous generator configuration
45 5 A CT / 400 Vac PT configuration
B Flush mounting
A2CDD06D09HI1I4JK24M Option/package configuration

 

The complete option string should be treated as a configuration identifier rather than assuming that every individual letter automatically represents a standalone feature. For replacement procurement, matching the complete configuration is preferable to matching only the basic model number

8440-1546 WOODWARD

8440-1546 Associated and Replacement Models
 
Part Number Model / Description Relationship
8440-1546 MFR2S45B/A2CDD06D09HI1I4JK24M Target product
8440-1936 EASYGEN-3500-5/P2 Similar replacement listed by Woodward-SEG
8440-1542 MFR2S41B/PSV+A2I3SB Related MFR2 configuration
8440-1528 MFR2S15B/PSV+A2I3SB Related MFR2 configuration
8440-1409 MFR2S45B/A2CD06D09HI1I4JK24MMB Related MFR2 configuration
8440-1335 MFR2S45B/PSV+A2I3SB Related MFR2 configuration
8440-1323 MFR2S45B/PSVA Related MFR2 configuration
8440-1287 MFR2S15B/PSVA Related MFR2 configuration

Woodward-SEG specifically lists 8440-1546 and identifies 8440-1936 / EASYGEN-3500-5/P2 as the similar item. It does not establish that every MFR2 configuration can be replaced by the same EasyGen model.

Original Woodward Manual / PDF

 
Installation and Commissioning
 

Woodward 8440-1546 / MFR2 is installed as part of a generator protection and control system. Before installation, confirm that the complete part number, configuration, power supply, CT/PT ratings, and I/O requirements match the existing application. The installation should be performed by qualified personnel familiar with generator protection, switchgear and electrical control systems.

01/

Disconnect the Existing Equipment

Before removing an existing MFR2, isolate the relevant control and measurement circuits according to the site's electrical safety procedures.

Do not disconnect CT circuits under load without following the site's approved CT isolation procedure.

02/

Record Existing Wiring

Before removing the original unit, photograph and record:

Terminal numbers/CT connections/PT connections/DC power connections/Digital inputs/Relay outputs/Communication wiring/Grounding/External control signals

This information can be used as a reference during installation of the replacement unit.

03/

Verify the Replacement

Compare the replacement unit with the original unit.

The following information should match:

Part Number → Configuration → CT/PT → I/O → Mounting → Application

Do not rely only on the external appearance.

04/

Mechanical Installation

Install the MFR2 into the existing control panel according to the applicable mounting arrangement.

Confirm that:

The unit is securely fixed.

No terminal is mechanically stressed.

Wiring has sufficient clearance.

Ventilation requirements are maintained.

The front panel can be accessed after installation.

05/

Electrical Connection

Reconnect the wiring according to the applicable Woodward documentation.

Particular attention should be given to:

DC Power → CT → PT → Digital Inputs → Relay Outputs → Communication

Incorrect CT/PT wiring can result in incorrect electrical measurements and protection behavior.

06/

Commissioning After Installation

After mechanical and electrical installation, the MFR2 should be commissioned before being returned to normal generator operation.

Visual Inspection→Power Supply Verification→Display / LED Check→Measurement Input Verification→Digital Input Verification→Relay Output Verification→Protection Parameter Verification→Synchronization Verification, if applicable→Generator Test→Final Operational Check

The exact commissioning sequence should follow the applicable MFR2 documentation and the site's approved commissioning procedure.

FAQ

Q: What type of generator is associated with the 8440-1546 configuration?

A: The configuration MFR2S45B identifies the synchronous-generator version in the MFR 2 model structure. The complete application should still be checked against the actual unit documentation.

Q: What CT configuration is associated with 8440-1546?

A: The 45 configuration is associated with a 5 A CT secondary and a 400 Vac PT secondary configuration. Verify the actual nameplate before replacement.

Q: What information should I provide when requesting a replacement?

A: Please provide:

Part Number + Quantity + Nameplate Photo + Application + Destination

For a replacement project, the existing wiring or configuration information is also helpful.

Q: Can you provide actual photos?

A: Yes. Actual front, rear, nameplate, packaging, and inspection photographs can be provided when available.

 

 

 

 

Hot Tags: 8440-1546, WOODWARD 8440-1546, 8440-1546 H, MFR2 8440-1546, MFR2S45B, MFR2S45B/A2CDD06D09HI1I4JK24M, Woodward Multifunction Relay