Parker Meggitt has always been committed to providing customers with the best measurement and monitoring solutions, helping you significantly enhance your equipment's performance. This naturally includes updating and replacing certain components within the product range, as well as simplifying the existing configuration options.
Accordingly, this letter is to inform you about the discontinuation of the following products or product configurations with immediate effect:
1) Vibration switches CVS100:
The following configurations are discontinued
• CVS100-A1-B01-C01-Dxx
• CVS100-A01-B02-C01-Dxx
• CVS100-A02-B01-C01-Dxx
• CVS100-A02-B02-C01-Dxx
These versions are replaced by the equivalent 2-relay versions (Option C02).
2) Vibration monitor VMS 830:
The VMS830 1-channel version is discontinued. It is replaced by the VMS830-2, which can monitor 2 channels, has a steel housing with a LCD display, and a 220 VAC or 24 VDC power supply
3) Transmitter 4-20 mA:
• The transmitters TAS202, TSG101 M1, TSG102 M1 are discontinued. They are replaced by our functional equivalent TSG201, TSG202 or VIbroSmart VSV301 / VSB300 modules
• The transmitters TSG201 and TSG201-2 are discontinued. They can be replaced by the form-fit equivalent TSG202-2R transmitter.
• The TSW211 SMAX is discontinued. It can be replaced by the functional equivalent ViIbroSmart VSV301/VSB300 module with 2x TQ902/IQS900.
• The TSW / TWW and TIW transmitters version - 001 with SMC connectors are discontinued and replaced by the standard version with triaxial connector.
• The TWW101 M1 and TWW212 are discontinued. They are replaced by our functional equivalent TWW 201, IQS910, or VibroSmart VSV301/VSB300 modules.
• The TIW101 M1 module is discontinued and replaced by the functional equivalent TIW201
4) Velocity sensor CV211:
The high temperature and low frequency versions are discontinued. They are replaced by our functional equivalent CV213 (for ATEX and high temperature) and VE210 (for low frequency). Cable lengths of 5m or 10 m are available.
5) EC cable and connectors:
Except for the EC-AE119-HT-Cx-Exxx-Gxxx that remains in the price list, the EC cables are replaced by functional, form, fit, equivalent EC318 and EC319. The connectors MS3106, MS3108, MS3206a and MS3208 are discontinued with no replacement; i.e., the correct extension cable must be purchased.
6) Proximity sensors WW:
• Proximity sensors WW07-001 and WW009-001 with BMC connectors are discontinued. They are replaced by our standard WW007 and WW009 sensors, with triaxial connectors.
• Sensor standard body length is 70 mm. Other lengths available are C20, C40, C100, C150 or C200
• Cable lengths available are either 1m, 5m or 10 m, with or without mechanical protection
• Due to obsolescence, sensor WW030 is discontinued. Functional equivalent is the TQ403, with an IQS900 signal conditioner
7) Displacement systems:
• Due to obsolescence, the old series U15, U22, U40 with the DT-350-I-M1 transmitter are discontinued. Functional equivalents are the RE022 and RE030 sensors with the RE101 transmitter.
• The RE102 transmitter is discontinued. They are replaced by the form-fit equivalent RE101-002 transmitter
• The high temperature AE119-050-R-HT inductive expansion probe and CFA110 conditioner are discontinued. Only the standard inductive expansion probe AE119-050- SK remains available
• The 100 mm range inductive expansion probe AE119-100-SK-S is discontinued. It is replaced by the Meggitt SA product, 800-119-000-12X