Description
Technical Parameters
Product Introduction
The Model 4119A Enhanced Intelligent Communication Module (EICM) allows the Tricon to communicate with Modbus masters and slaves, TriStation 1131, and printers.
For Modbus connections, the EICM user can select the RS-232 point-to point interface for one master and one slave, or the RS-485 interface for one master and up to 32 slaves. The RS-485 network trunk can be one or two twisted-pair wires up to a maximum of 4,000 feet (1,200 meters).
Technical Specifications
|
Brand |
TRICONEX |
|
Model |
4119A |
|
Part Number |
4119A |
|
Description |
TMR Enhanced Intelligent Communication Module
|
|
Origin |
USA |
|
Dimension |
50*48*8cm |
|
Weight |
4.58kg |
Product Details
Each EICM contains four serial ports and one parallel port which can operate concurrently.
Each serial port can be configured as a Modbus master with up to seven Modbus masters per Tricon chassis. A single Tricon system supports a maximum of two EICMs, which must reside in one logical slot. (The hot-spare feature is not available for the EICM, though you can replace a faulty EICM while the controller is online.) Each serial port is uniquely addressed and supports either the Modbus or TriStation interface.
Each serial port can be configured as a Modbus master with up to seven Modbus masters per Tricon chassis. A single Tricon system supports a maximum of two EICMs, which must reside in one logical slot. (The hot-spare feature is not available for the EICM, though you can replace a faulty EICM while the controller is online.) Each serial port is uniquely addressed and supports either the Modbus or TriStation interface.
Modbus communication can be performed in either RTU or ASCII mode. The parallel port provides a Centronics interface to a printer.
Each EICM supports an aggregate data rate of 57.6 kilobits per second (for all four serial ports).
Programs for the Tricon use variable names as identifiers but Modbus devices use numeric addresses called aliases. Therefore an alias must be assigned to each Tricon variable name that will be read by or written to a Modbus device. An alias is a five-digit number which represents the Modbus message type and the address of the variable in the Tricon. An alias number is assigned in TriStation 1131.
EICM Specifications:
|
Model Number
|
4119A, Isolated
|
|
Serial ports
|
4 ports RS-232, RS-422 or RS-485
|
|
Parallel ports
|
1, Centronics, isolated
|
|
Port isolation
|
500 VDC
|
|
Protocol
|
TriStation, Modbus
|
|
Modbus functions supported
|
01 - Read Coil Status
02 - Read Input Status
03 - Read Holding Registers
04 - Read Input Registers
05 - Modify Coil Status
06 - Modify Register Content
07 - Read Exception Status
08 - Loopback Diagnostic Test
15 - Force Multiple Coils
16 - Preset Multiple Registers
|
|
Communication speed
|
1200, 2400, 9600, or 19,200 Baud
|
|
Diagnostic Indicators
|
Pass, FaULT, Active
TX (Transmit) - 1 per port
|
|
RX (Receive) - 1 per port
|
RELATED PRODUCTS
| TRICONEX 8111 | Triconex 4000103-510 |
| TRICONEX T2652-5 | Triconex 4000094-110 |
| TRICONEX 8305 | Triconex 3636R |
| TRICONEX 3624 | Triconex 3510 |
| TRICONEX 2661-8 | Triconex 4119A |
| TRICONEX 2652 -310 | Triconex 9763810 |
| TRICONEX 8300A | TRICONEX 3000109-300 |
| TRICONEX 4201 | TRICONEX 3000280-000 |
| Triconex 9661610 | TRICONEX 3611E |
| TRICONEX 2551-6 | Triconex 4351B |
| TRICONEX2651-6 | Triconex 8100-8 |
If you have any order needs, please feel free to contact our sales manager: