Product Introduction
KJ4101X1-BC1 (12P1872X022) is part of the Emerson DeltaV system. This power supply carrier is designed for the DeltaV automation system to provide power to various modules and devices in the control system.
Technical Specifications
|
Manufacture |
EMERSON |
|
Model |
KL2102X1-BA1 |
|
Part Number |
12P5030X032 |
|
Description |
Wireless I/O Card (WIOC) |
|
MoOrigin |
USA |
|
Dimension |
26*16*6cm |
|
Weight |
0.43kg |
Product Details
EMERSON KL2102X1-BA1 is configured with intelligent switch and DeltaV compatible settings. It can be directly installed and converted into a compatible DeltaV network. It can fully support DeltaV network communication without user configuration and does not rely on the configuration of existing switches or network devices. It can automatically adapt to 100/1000 communication, full-duplex or auto-negotiation mode.
| Hazardous Atmosphere |
II 3G Ex ec IIC Gc
FM19ATEX0173U
IECEx FMG 19.0019U
FM21UKEX0017U
CL. I Div. 2 GP. A,B,C,D
CL. I Zone 2 AEx/Ex ec IIC Gc
FM17CA0145U
FM17US0286U
| Power Specifications |
| Environmental Specifications |
Ambient Temperature -40 °C to +70 °C
Shock 10g ½ Sinewave for 11msec
Vibration 1mm Peak to Peak from 2 to 13.2Hz; 0.7g from 13.2 to 150Hz
Airborne Contaminants ISA-S71.04 –1985 Airborne Contaminants Class G3
Relative Humidity 5 to 95% Non-Condensing
Terminal Block key Position D2
Note: Refer to the product label for serial number and location and date of manufacture.
Warning: This product has specific instructions for installation, removal and operation in hazardous areas. Refer to document 12P5403 "DeltaV™ Electronic Marshalling Digital Automation System (CHARM I/O Subsystem) Zone 2 Installation Instructions". Other installation instructions are available in the "DeltaV™ S-Series and CHARMs Hardware Installation" manual.
| Removal and Insertion |
Field power supplied to this device, either at the field terminal or as bussed field power through the Carrier, must be removed before removing or connecting the device.
This unit cannot be removed or inserted with system power energized unless the area is known to be non-hazardous.
A rotary keying system ensures compatibility between I/O cards and terminal blocks after installation is complete. The terminal block must have the keys set for the I/O card with which it is to be used.
| Maintenance and Adjustment |
This unit contains no user serviceable parts and should not be disassembled for any reason. Calibration is not required.
Shipping Term
TNT,DHL,FEDEX,UPS etc.

| Ms.Smiling Sales Manager┃CHINA |
| Atten:Smiling |
| Mobile/WhatsApp/Wechat:+86 18050035902 |
| E-mail: info@htechplc.com |
| Website: https://www.joyoungintl.com/ |
| Address: Room 1904, No.96-2 Lujiang Road, Siming District, Xiamen,China. |












