Product Introduction
PP885 3BSE069276R1 is a high-performance industrial touchscreen from ABB's Panel 800 series, Version 6. It features a 15.4-inch TFT-LCD widescreen (some models are labelled 15 inches) with a base resolution of 1280×800 pixels. The derivative PP885R has a resolution of 1024×768 pixels. It supports 262,000 colours, has a brightness of 400-450 cd/m², an LED backlight lifespan of over 50,000 hours, and a 170° viewing angle, enabling it to clearly display complex industrial data and process diagrams.

Technical Specifications
|
Manufacture |
ABB |
|
Model |
PP885 |
| Part Number | 3BSE069276R1 |
|
Description |
Process Panel |
|
Origin |
Sweden |
|
Dimension |
42*28*7cm |
|
Weight |
3.85 kg |
Product Details
All 3BSE069276R1 PP885 Panel 800 Version 6 are developed to satisfy the demands of human-machine communication. Built-in functions such as displaying and controlling text, dynamic indication, time channels, alarm and recipe handling are included.
The Panel 800 Version 6 works primarily in an object-oriented way, making it easy to understand and use. Configuration is carried out on a PC using the Panel Builder configuration tool. The project can then be transferred and stored in the operator panel itself.
Various types of automation equipment, such as PLCs, servos or drives, can be connected to the Panel 800 Version 6. In this manual, the term "the controller" refers to the connected equipment.
Installation Process:
The following is needed: • A Torx TX7 screwdriver
1. Unpack and check the delivery. If damage is found, notify the supplier.
2. Place the operator panel on a stable surface during installation. Dropping the operator panel or letting it fall may cause damage.
3. To cut a correct opening for the operator panel, use the cut-out dimensions in the outline drawing.
4. Secure the operator panel in position by screwing the M4 Torx screw, allowing the built-in bracket to tighten against the panel:
5. Connect the cables in the specified order, according to the drawing and steps below
• The operator panel must be brought to ambient temperature before it is started up. If condensation forms, ensure that the operator panel is dry before connecting it to the power outlet.
• Ensure that the operator panel and the controller system have the same electrical grounding (reference voltage level); otherwise, communication errors may occur.
• Ensure that the voltage and polarity of the power source are correct.
• Separate high voltage cables from signal and supply cables.
• Shielded communication cables are recommended.

– Connect cable A
– Connect cable B, using an M5 screw and a grounding conductor (as short as possible), that is sized correctly according to local electrical codes.
– Connect cable C.
– Connect cable D. The recommended cross-section of the cable is 1.5mm²2.
6. Carefully remove the protective film over the operator panel display, taking care to avoid static electricity that could damage the panel.