CP502 143-502-000-061 Piezoelectric Pressure Transducer

CP502 143-502-000-061 Piezoelectric Pressure Transducer

Item Number:CP502
Price: $8888(Please note that product prices may vary due to market fluctuations. Contact us for the latest quotation and availability.)
Lead Time: Available — Please confirm current inventory before placing an order.
Condition: New
Payment: T/T
Shipping Port: Fujian, China
Send Inquiry
Description
Technical Parameters
CP502 143-502-000-061 Piezoelectric Pressure Transducer

CP502 143-502-000-061 is a piezoelectric dynamic pressure transducer designed for high-temperature pressure measurement and combustion monitoring applications, particularly in gas turbine systems. The sensor uses GaPO4 piezoelectric technology and is intended for dynamic pressure measurement in demanding industrial environments.

Product Availability

Stock Status: Contact us for current inventory
Lead Time: Confirmed according to current stock and order quantity
Condition: New Original / Unused - confirm actual condition before ordering
Shipping: DHL / FedEx / UPS / International Express

Request a Quote for CP502 143-502-000-061

Important: Please provide the complete part number 143-502-000-061 when requesting a quotation. CP502 is a product family with multiple part-number configurations, so the complete ordering number should be verified before replacement.

Parameter Information
Product Family CP502
Product Type Piezoelectric Pressure Transducer
Sensor Technology Piezoelectric
Part Number 143-502-000-061
Application Category Vibration & Dynamic Pressure Monitoring
Primary Application Gas Turbine Dynamic Pressure Monitoring
Measurement Type Dynamic / Pulsating Pressure
Sensing Material GaPO4 Gallium Phosphate
Temperature Range -70 to 560 °C*
Frequency Range Up to 15 kHz*
Sensitivity 85 pC/bar*
Overload Up to 100 bar*
Connection Integral mineral-insulated cable with connector*
Origin Switzerland
Condition New / Unused - subject to actual stock
Warranty 12 Months
Dimension 18*18*7cm
Weight 0.35kg
HS code 9026900090

 

Technical values should be verified against the applicable CP502 configuration and original documentation before engineering use. Public CP502 documentation gives these values for the product family rather than necessarily every individual ordering suffix.

CP502 Manual Download

 

What Is CP502 143-502-000-061?

 

 

CP502 143-502-000-061 is a Piezoelectric Pressure Transducer used to measure pressure fluctuations rather than only static process pressure.

 

The CP502 belongs to the Pressure Transducer family developed for applications such as gas turbine combustion monitoring and control. Its GaPO4 sensing element is designed for temperature operation and dynamic pressure measurement.

 

This distinction is important for procurement:

CP502 is not a conventional 4–20 mA process pressure transmitter.

It is a piezoelectric dynamic pressure transducer, producing a charge-type measurement signal that is typically processed by a compatible measurement, signal-conditioning, or monitoring system.

How CP502 Works

 

 

The basic measurement chain can be represented as:

Combustion Chamber / Pressure Source
↓
CP502 Pressure Sensor
↓
Piezoelectric Signal
↓
Signal Conditioning
↓
Monitoring / Control System
↓
Dynamic Pressure Analysis

 

The sensor detects pressure fluctuations and converts the mechanical pressure changes into an electrical charge signal.

Because CP502 is intended for dynamic measurements, the complete measurement chain should be considered when replacing the sensor. The sensor, cable/connector configuration, signal conditioning equipment, and monitoring system should be checked together.

 

Piezoelectric Pressure Transducer CP 502

Key Technical Features

 

 

GaPO4 Piezoelectric Technology

The CP502 uses gallium phosphate (GaPO4) as its piezoelectric sensing material. Public technical documentation identifies GaPO4 as the sensing technology used in this high-temperature dynamic pressure sensor family.

The material is particularly suited to applications where temperature changes and dynamic pressure signals must be considered simultaneously.

High-Temperature Measurement

Published CP502 documentation specifies an operating temperature range of approximately:

-70 to +560°C

This makes the sensor suitable for demanding high-temperature measurement locations associated with gas turbine combustion systems.

Dynamic Pressure Measurement

CP502 is designed for measuring pressure pulsations and dynamic combustion pressure.

Typical measurement targets include:

Combustion pressure pulsations

Dynamic pressure fluctuations

Combustion instability

Transient combustion behavior

Gas turbine combustion dynamics

Typical Applications

Gas Turbine Combustion Monitoring

The primary application of the CP502 family is dynamic pressure measurement in gas turbine combustion systems. Public documentation specifically identifies gas turbine combustion chamber monitoring and control as application areas.

Possible applications include:

Combustion dynamics monitoring

Combustion pressure analysis

Closed-loop combustion control

Emissions-related combustion control

Transient operating condition monitoring

Gas Turbine Development Testing

CP502 can also be used in development and test environments where dynamic pressure measurements are required.

 

Typical applications include:

Gas turbine development

Combustion testing

Performance testing

Research laboratories

Prototype turbine testing

CP502 143-502-000-061 vs. Other CP502 Part Numbers
 

The CP502 product family contains multiple 143-502-000-xxx part numbers, including publicly listed examples such as:

Part Number Product Family
143-502-000-021 CP502
143-502-000-031 CP502
143-502-000-041 CP502
143-502-000-051 CP502
143-502-000-061 CP502
143-502-000-121 CP502
143-502-000-122 CP502
143-502-000-131 CP502
143-502-000-132 CP502
143-502-000-141 CP502
143-502-000-142 CP502
143-502-000-151 CP502
143-502-000-152 CP502

These part numbers should not automatically be treated as interchangeable. The suffix can identify different mechanical, cable, connector, or application configurations.

 

Replacement Rule

Always match the complete part number rather than ordering by "CP502" alone.

 

For a replacement project, verify:

Complete part number

Sensor mechanical configuration

Cable configuration

Connector

Pressure range

Temperature requirement

Signal-conditioning equipment

Existing system documentation

Related Vibro-Meter Piezoelectric Pressure Transducer
  • CP 502  CP 505

    For internal linking and product-family navigation, you can create a dedicated Dynamic Pressure Sensors section.

Model Product Type Typical Position
CP502 High-temperature dynamic pressure transducer Gas turbine combustion monitoring
CP505 High-temperature dynamic pressure transducer Gas turbine applications
CP211 High-temperature dynamic pressure sensor Extreme-temperature measurement
CP216 High-temperature dynamic pressure sensor Industrial / OEM applications
CP235 High-sensitivity dynamic pressure sensor Dynamic pressure measurement
 
FAQ

Q: What is the difference between CP502 and a conventional pressure transmitter?

A: CP502 is designed for dynamic pressure measurement using piezoelectric sensing technology. It should not be treated as a conventional static-pressure transmitter with a standard 4–20 mA output.

Q: What material does CP502 use?

A: The CP502 family uses GaPO4 (gallium phosphate) piezoelectric sensing technology.

Q: Is 143-502-000-061 interchangeable with other CP502 part numbers?

A: Not automatically.

The CP502 family contains multiple 143-502-000-xxx configurations. The complete part number should be matched before replacement.

Q: What information should I provide for an RFQ?

A: Please send:

Part Number: 143-502-000-061

Required Quantity

Required Condition

Destination Country

Required Delivery Date

Any required certificate

 

 

 

 

 

 

Hot Tags: 143-502-000-061, CP502 143-502-000-061, Piezoelectric Pressure Transducer CP 502, CP502-143-502-000-061 datasheet, Vibration Monitoring 143-502-000-061