T8480 ICS Triplex TMR Analog Output Module

T8480 ICS Triplex TMR Analog Output Module

Item Number:T8480
Brand: ICS TRIPLEX
Price: $5000
Lead Time: In stock
Condition: New
Payment: T/T
Shipping Port: Fujian,China
Send Inquiry
Description
Technical Parameters
Product Introduction

ICS T8480 TMR 4-20 mA Analog Output Module is a member of the Trusted range of input/output (I/O) Modules. All Trusted I/O Modules share common functionality and form. At the most general level, all I/O Modules interface with the Inter-Module Bus (IMB), which provides power and enables communication with the TMR Processor. In addition, all Modules have a field interface that is used to connect to Module-specific signals in the field. All Modules are Triple Modular Redundant (TMR).

T8480 ICS

Technical Specifications

 

Manufacture

ROCKWELL ICS TRIPLEX

Model

T8480

Description

Trusted TMR Analog Output Module

Output channel

40 Channel
Output signal 0–20 mA / 4–20 mA

Origin

USA / Mexico

Dimension

32*30*28cm

Weight

1.3kg

 

Product Details 

Module structure composition

The T8480 Analog Output Module is mainly composed of four core components internally:
1) Host Interface Unit (HIU)
HIU is the interface unit between the module and the system backplane bus, and is responsible for:
Carry out high-speed communication with the controller
Power distribution of the processing module
Operation status of the management module
This section also includes three independent processing units (A, B, C), which correspond to the three redundant paths in the TMR architecture.

 

2) Field Interface Unit (FIU)
FIU is responsible for achieving signal interaction with the on-site equipment. Its main functions include:
Simulation signal output control
Output current monitoring
On-site power voltage monitoring
Load detection
FIU is also an important component for performing line diagnostics.

 

3) Field Termination Unit (FTU)
FTU is a field wiring terminal interface unit, used for connecting field devices.
Its main functions include:
Signal conditioning
Overvoltage protection

EMI / RFI interference resistance
Fault safety switching
FTU also provides the necessary electrical isolation and wiring interfaces.

 

4) Front Panel Unit (FPU)
The front panel of the module provides:
LED status indicator light
Output status display
Module Health Status Indicator
Through these indicator lights, engineers can quickly determine the working status of the module.

 

T8480 Installation

The T8480 module is usually installed in:
Trusted Controller Chassis

Trusted Expander Chassis

Connected to the system controller via the backplane bus.

 

Connection method:
The on-site equipment is connected through the Field Termination Unit (FTU) access module.

 

Cable Selection

I/O cables suitable for use with the Trusted TMR Analog Output Module are detailed in these Product Descriptions:

• Trusted I/O Companion Slot Cables

• Trusted TMR I/O SmartSlot Slot Cables

The Product Descriptions also detail the types of Field Termination Assembly (FTA) or Versatile Field Termination Assembly (VFTA) which may be used with the type of Module.

 

How to check the status of the running indicator light

Status indicators on the Front Panel of the Module provide visual indications of the Module's operational status and field output status. Each indicator is a bicolor LED. At the top and bottom of each Module is an ejector lever that is used to remove the Module from the Chassis. Limit switches detect the open/closed position of the ejector levers. The ejector levers are normally latched closed when the Module is firmly seated into the Controller or Expander Chassis.

T8480 Module Front Panel

 

Module Status LEDs
INDICATOR STATE DESCRIPTION
Healthy

Off

Amber

Green

Red – flashing

Red (momentary)

Red

No power applied to the Module.

Slice is in the startup state momentarily after installation or power-up.

Slice is healthy.

Fault present on the associated slice, but the slice is still operational.

On installation, power is applied to the associated slice.

The associated slice is in the fatal state. A critical fault has been detected, and the slice is disabled.

Active

Off

Green

Red – flashing

Red – flashing

The module is not in the Active state.

Module is in the Active (or Maintain) state.

The module is in the shutdown state if the Standby LED is off.

The module is in a fatal state if the Standby LED is also flashing.

Standby

Off

Green

Red – flashing

The module is not in the Standby state.

The module is in the Standby state.

The module is in a fatal state. The Active LED will also be flashing red.

Educated

Off

Green

Green – flashing

Amber -Flashing

The module is not educated.

The module is educated.

The module is recognized by the Processo,r but education is not complete.

Active/Standby changeover in progress.

 

FAQ

Q: What are the main functions of ICS T8480?

A: The main functions of this module include:
Provide 40 channels of analog current output
Supports 0–20 mA or 4–20 mA signals
The triple redundancy architecture ensures system security.
Automatic line monitoring and fault detection
Overcurrent protection and self-diagnosis function

Q: What is the security level of ICS T8480?

A: The ICS T8480 has obtained the IEC 61508 SIL3 safety integrity level certification and is suitable for control systems with high safety standards.

Q: What issues should be noted when purchasing the ICS T8480?

A: When purchasing this module, please pay attention to the following points:
Confirm whether the model is the original T8480 model
Confirm that the module version is compatible with the Trusted TMR system.
Check whether the module is a brand-new or refurbished product.
Confirm whether it includes terminal components or FTU
Confirm whether the supplier provides warranty and technical support.

 

 

 

 

 

 

Hot Tags: T8480,ICS T8480,ICS Triplex T8480,Trusted TMR Analog Output Module,SIL3 Safety Control System Module