ABB 3BSE013262R1 CI810A AF100 Field Comm. Interface

ABB 3BSE013262R1 CI810A AF100 Field Comm. Interface

Item Number:CI810A 3BSE013262R1
Brand: ABB
Price: $800
Lead Time: In stock
Condition: New
Payment: T/T
Shipping Port: Fujian,CN
Send Inquiry
Description
Technical Parameters
Product Introduction

CI810A 3BSE013262R1 AF 100 Fieldbus communication interface module is used to connect field devices with the controller. It can support efficient and stable data exchange between field devices and the controller through two AF100 modems and can operate in complex industrial sites, distributed I/O architectures, and demanding control environments.

 

Technical Specifications

 

Manufacture

ABB

Model

CI810A
Part Number 3BSE013262R1

Description

Communication Interface Module

Origin

Sweden

Communication Protocol Advant Fieldbus 100
Installation method DIN rail or frame installation

Dimension

21*16*14cm

Weight

0.56kg

 

Product Details

Communication Interface Module 3BSE013262R1
 

If you want to know more about the products, please feel free to contact info@htechplc.com at any time.

product-540-461
 

3BSE013262R1 CI810A was originally developed by ABB for data transmission between field devices and controllers in its distributed control system. It is a point-to-multipoint fieldbus protocol that can be used for communication among multiple I/O modules, instruments, sensors, and controllers.

 

The AF100 communication protocol has the following core features:
Real-time and deterministic on-site data exchange capability - suitable for process control and rapid I/O feedback;
Support dual redundancy or multi-link redundancy - to enhance the system's fault-tolerance capability;
Completely compatible with the ABB S800 I/O system - can be seamlessly integrated into the ABB 800xA platform or other DCS architectures;

 

The "CI810" series includes CI810, CI810V1, CI810V2, and CI810A, all of which are different versions or updated models of the AF100 Fieldbus communication interface.

 

Product advantages

Why choose 3BSE013262R1 CI810A
 

Enable the on-site equipment to "speak safely.y"
The CI810A 3BSE013262R1 Communication Interface uses an independent communication channel to enable the data from distributed on-site equipment to be reliably collected and transmitted, ensuring that the control system can grasp the on-site status in real time and reducing the risks of information omission or error transmission.

 

Clearly define communication responsibilities and simplify system maintenance.e
As an independent node of the on-site communication layer, it separates data transmission and control logic, enabling engineers to quickly identify network issues, independently upgrade or maintain communication modules without interfering with the core control functions.

 

To provide flexible space for phased expansion and renovation
During system expansion or phased construction, the communication interface of CI810A 3BSE013262R1 can seamlessly connect with new devices and network nodes, making the upgrade of the on-site network more flexible and reducing interference to the production line operation.

 

Stable communication, reduction of operational hidden risks
The CI810A 3BSE013262R1 Communication Interface maintains stable communication under long-term operation conditions. Even in environments with a large number of nodes and complex networks, it can reduce system anomalies or interruptions, thereby enhancing the reliability of the entire automated system.

 

Supporting engineering efficiency and system transparency
By providing operational status feedback and network information, the CI810A not only enables engineers to grasp the health status of the on-site network but also provides system transparency to the decision-making level, optimizing maintenance plans and operational cost control. ol

 

Technical Q&A

Q1: What kind of system role does CI810A typically play in the AF100 network?
The CI810A mainly assumes the roles of a fieldbus interface and network node management, used to establish a stable data channel between the AF100 network and the upper-level control system. It does not participate in control logic operations, but is responsible for the organization, transmission, and status maintenance of on-site data, enabling the control system to orderly access distributed on-site information.


Q2: When expanding the system, will the CI810A interfere with the topology planning of the AF100 network?
When expanding the network, the CI810A usually serves as a fixed communication interface node. The quantity and location of these nodes will have an impact on the segment division, link length,h, and node distribution of the AF100 network. Therefore, during the expansion design phase, it is often necessary to combine the bus load and physical wiring conditions to plan the deployment location of the CI810A.


Q3: What actual impact does CI810A have on the real-time performance of on-site communication?
The CI810A manages the AF100 data through its internal processing mechanism, which can, to some extent, balance the data refresh cycle and communication stability. In typical applications, it helps maintain the continuity of on-site data updates, but the overall real-time performance still depends on the network scale, the number of nodes, and the system configuration method.


Q4: During its long-term operation, what aspects does the maintenance priorities of CI810A mainly focus on?
The maintenance work mainly focuses on monitoring communication status, interface connection reliability, and the operation quality of the fieldbus, rather than the internal components of the modules. By observing the communication error rate and link status changes through system diagnostic tools, it is possible to identify potential network issues in advance.


Q5: Does the CI810A require separate parameter configuration or address setting?
During the system configuration process, the CI810A usually needs to define the network-related parameters in the engineering software, such as node identification, communication relationships, and network mapping. These settings are generally completed during the system debugging stage and are rarely adjusted frequently during operation.

 

 

 

 

 

Hot Tags: 3BSE013262R1,ABB 3BSE013262R1,CI810A 3BSE013262R1,ABB CI810A,CI810A AF100 Field Comm. Interface, sortation systems, abb advant 800xa, cooling systems, cartoners, stepper motors, robotics components